Hydraulic oil transfers power, lubricates moving parts, removes heat and prevents corrosion in hydraulic systems. When hydraulic oil overheats and runs at excessive temperature, it oxidizes rapidly, loses proper viscosity, and accelerates wear of seals, pumps, cylinders and valve blocks. Common failures including internal leakage, sluggish movement, valve sticking and abnormal noise will appear. It is essential for maintenance technicians to identify heat sources and carry out systematic inspections.
1.1 Cooling System Malfunction
Blocked heat exchangers, oily and dusty cooling fins, failed cooling fans, insufficient cooling water flow or clogged water channels are the most frequent reasons. Heat cannot dissipate out of the circulation loop. Bypass valves stuck open will also make hot oil skip the cooler directly back to the tank.
1.2 Wrong Hydraulic Oil Grade or Degraded Oil
Oil viscosity mismatch creates extra flow friction. Too high viscosity increases resistance at low temperature; too low viscosity reduces lubrication and raises internal leakage. Aged, contaminated or water-emulsified hydraulic oil generates extra friction heat. Low oil level reduces heat storage and circulation capacity of the tank.
1.3 Excessive Internal Leakage of Hydraulic Components
Worn hydraulic pumps, relief valves, directional valves, counterbalance valves and cylinder seals cause heavy internal leakage. High-pressure oil throttles continuously, converting pressure energy into heat. A relief valve stuck open or keeping continuous overflow is a typical heat source.
1.4 Improper Working Conditions & Overload
Continuous overload, frequent pressure holding and dead-heading keep the system under high pressure. Undersized pipes, excessive elbows and unnecessary throttle points add flow resistance and produce friction heat.
1.5 Suction & Return Line Troubles
Clogged suction filters and air leakage on suction lines cause cavitation inside the pump. High return backpressure slows oil flow, so oil cannot cool down sufficiently inside the reservoir.
1.6 Assembly and Commissioning Errors
Misaligned pump coupling creates mechanical friction and transfers heat to the pump housing. Improper pressure settings keep the system running at unnecessarily high pressure.
Use an infrared thermometer to measure oil temperature in the tank, inlet and outlet of the cooler, pump housing and valve manifold. The recommended working temperature range for most hydraulic systems is 30~55°C. Temperature above 60°C is abnormal, and shutdown inspection is required once over 70°C. Verify the hydraulic oil level meets the marked range.
For air-cooled systems: Clean dust and grease on cooling fins. Test cooling fan motor, relay and temperature control switch, confirm the fan activates at the set trigger temperature.For water-cooled systems: Check water supply valves, inlet filters and flow rate. Remove scale and dirt inside the water cooler.Confirm no bypass shortcut allows hot oil to avoid the heat exchanger.
Take an oil sample to check color, clarity and emulsification. Dark, cloudy or milky oil indicates severe degradation. Test viscosity and contamination level. Replace with the specified hydraulic fluid and clean the tank if the oil fails inspection.
Start the equipment under no-load condition and observe temperature rising speed. If oil heats up quickly without load, focus on the relief valve. Disassemble, clean the spool and spring to remove trapped dirt.Measure internal leakage of pumps, cylinders and valve groups separately to locate the heat source, especially counterbalance valves and check valves under constant pressure.
Listen for cavitation noise from the hydraulic pump. Inspect suction filters and suction lines for blockage or air intake. Check crushed pipelines and excessive bends. Calibrate pump coupling alignment to eliminate mechanical friction heat.Compare actual working pressure with set pressure, confirm the system is not staying in continuous overflow.
Replace hydraulic oil and filters on schedule, clean coolers regularly. Avoid long-time dead-heading and overload operation. Select properly sized hydraulic pipes. Set reasonable working pressure to reduce useless overflow loss. Early detection of temperature rise can avoid permanent damage to expensive hydraulic components.
Contact: Mr.Qiu
Phone: 18959452627
E-mail: qiuyueyun@lyunite.com
Whatsapp:+8618959452627
Add: Room 1502, Unit 1, Building 5, No.1 Wuxing Road, Xinluo District, Longyan City, Fujian Province